Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Contacts Login 
Home Print this page Email this page Users Online: 2246

ORIGINAL ARTICLE
Year : 2014  |  Volume : 2  |  Issue : 1  |  Page : 21-25

Comparison of radiopacities of different flowable resin composites


1 Department of Dentomaxillofacial Radiology, Suleyman Demirel University, Isparta, Turkey
2 Department of Restorative Dentistry, Suleyman Demirel University, Isparta, Turkey

Correspondence Address:
Derya Yildirim
Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Suleyman Demirel University, Dogu Kampus Cunur - 32260, Isparta
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2321-3841.133562

Rights and Permissions

Objectives: Radiopacity can facilitate diagnostic observations adjacent to flowable resin composites. The aim of this study was to evaluate the radiopacity of the current low viscosity flowable resin composites and to compare them with human dental tissues. Materials and Methods: Five specimens of seven flowable light cured composite materials with a thickness of 2 mm were prepared and radiographed alongside an aluminum stepwedge, human enamel and dentin. Three standart occlusal radiographs for each material were taken with exposure time of 0.32 seconds and focus-film distance of 40 cm. Films were processed in an automatic device, and digitized using a desktop scanner. Mean gray values of the materials, stepwedge, enamel and dentine were measured using Image J software. The data were analyzed using the Duncan multiple range test. Results: The mean gray values of flowable resin composites ranged from 26.61 ± 1.45 to 38.38 ± 1.47. The radiopacity values of the materials evaluated were in decreasing order: G-aenial Flo, Filtek Ultimate Flowable, Flowline, Estelite Flow Quick, Leaddent Flow, Supraflow, Bright Light Flow. All flowable resin composites, except Bright Light Flow, demonstrated significantly greater radiopacity values than 2 mm of the aluminum scale and dentin (P < 0.05). The radiopacity of only one flowable composite, G-aenial Flo, was found to be significantly higher from enamel (P < 0.05). Conclusions: All investigated materials presented radiopacity values above the minimum recommended by the international organization for standardization.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed8581    
    Printed284    
    Emailed0    
    PDF Downloaded611    
    Comments [Add]    
    Cited by others 6    

Recommend this journal